Tribo-Fatigue (TF) TF: Main Terms New Research Field Methodology of TF Stages of Progress of TF SI-SeriesTest Machines Results of WFT TF: Standards TF: Intern. Symposiums Books Contacts

 

 

TECHNICAL CHARACTERISTICS OF SI-SERIES MACHINES 

 
 
 

 

Description of indicators

 

Parameters

SI-01 machine

SI-02 machine

SI-03-M machine

Basic friction pair

cylinder-block

cylinder-roller

cylinder-block, cylinder-roller

Diameter of the working portion of the specimen, mm

10

10

10

Dimensions of the counterspecimen, mm

10x10x11.5

ø100

10x10x11.5

 ø100

Relubrication intervals

drop-feed lubrication

R.p.m. range of the specimen, min-1

40-4,000*

3,000

600-6,000

R.p.m. range of the counterspecimen, min-1

-

50-500

50-500

Range of bending loads, N

70-700

70-700

10-800

Range of contact loads, N

10-500

10-1,000

10-2,000

Error tolerance of load measurements, %

2

2

1

Range of measurement of the total wear of a specimen and a counterspecimen, μm

10-2,000

10-3,000

10-4,000

Error tolerance of wear measurements, of the total wear of a specimen and a counter-specimen, %, not more than

±3

±3

± 1

Range of measurement of the friction torque, Nm: 
- in sliding friction 
- in rolling friction

 

0.01-1.2

-- 

 

--

0.2-20

 

0.01-1.5 

0.2-30

Error tolerance of the friction torque measurements, %, not more than

3

3

2

Installed power of electrical equipment, kW

2.0

2.5

2.0

 

* ForSI-01-S: 1,000-18,000 min-1. 

SI-series machines will help you to solve quickly the most intricate problems of experimental evaluation and increase of the reliability of most essential units of modern machinery both on the individual criteria of resistance to fatigue and wear and complex criteria of resistance to wear-fatigue damage

 

Up ] Schemes of WF tests ] Test specimens ] [ Technincal characteristics ]